Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Orthopaedic Trauma ; (12): 512-517, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992741

RESUMO

Objective:To evaluate open reduction and internal fixation via the anterior approaches in the treatment of geriatric acetabular fractures.Methods:Retrospectively analyzed were the clinical data of 74 consecutive patients with acetabular fracture who had been treated by open reduction and internal fixation via the anterior approaches from June 2018 to December 2020. The patients were divided into 2 groups. In the geriatric group (≥65 years old): 16 patients [8 males and 8 females with an age of (74.0±5.9) years]; 7 both column fractures, 4 anterior column fractures, and 5 anterior column plus posterior hemi-transverse fractures according to the Letournel-Judet classification; time from injury to operation: (6.1±3.4) d. In the young group (<65 years old): 58 patients [48 males and 10 females with an age of (46.7±10.9) years]; 28 both column fractures, 14 anterior column fractures, 8 anterior column plus posterior hemi-transverse fractures, 5 T type fractures and 3 transverse fractures; time from injury to operation: (5.4±2.7) d. The 2 groups were compared in terms of operation time, intraoperative blood loss, postoperative reduction, operative complications, and functional results.Results:The 2 groups were comparable because there was no significant difference in the preoperative general data like fracture Letournel-Judet classification or dome impaction between them ( P>0.05). The intraoperative blood loss in the geriatric group was (715.6±285.0) mL, significantly less than that in the young group [(1,008.6±463.9) mL]( P<0.05). In the geriatric and young groups, respectively, the operation time was (167.2±44.3) min and (172.9±56.6) min, 3 and 6 cases had main operative complications, the good to excellent rate of postoperative reduction was 87.5% (14/16) and 84.5% (49/58), and the follow-up time was (26.6±10.7) months and (23.6±10.1) months, all showing no significant difference ( P>0.05). According to the improved Merle d'Aubigné & Postel scoring system, the hip function at the last follow-up was evaluated as excellent in 5 cases, as good in 10 cases, and as fair in 1 case in the geriatric group while as excellent in 21 cases, as good in 33 cases, and as fair in 2 cases (the other 2 cases were lost) in the young group, showing no statistically significant difference between the 2 groups ( P>0.05). Conclusion:Open reduction and internal fixation via the anterior approaches is as safe and effective for the geriatric patients with acetabular fracture as for the young and middle-aged ones.

2.
Chinese Journal of Orthopaedic Trauma ; (12): 470-477, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992735

RESUMO

Objective:To investigate the early clinical effectiveness of using customized 3D printed acetabular augment to repair large acetabular bone defects in delayed total hip arthroplasty after failed treatment of acetabular fractures.Methods:A retrospective study was conducted to analyze the 6 patients who had undergone 3D printed acetabular augment to reconstruct acetabular bone defects in delayed total hip replacement from July 2021 to January 2023 after failed treatment of acetabular fractures. They were all males, with an age of (51.3±15.0) years. Paprosky classification: 2 cases of type ⅡB, 1 case of type ⅡC, and 3 cases of type ⅢA. Recorded were surgical time, intraoperative bleeding, hospitalization time, and visual analogue scale (VAS), and modified Merle d'Aubigné & Postel score, Harris hip score, and leg length discrepancy at the last follow-up.Results:For the 6 patients, the mean surgical time was (222.5±46.9) min, the mean intraoperative bleeding 1,100 (1,000, 2,625) mL, the mean hospitalization time (9.0±4.5) d, and the mean follow-up time (11.8±7.9) months. At the last follow-up, the VAS [(2.5±1.0) points] significantly decreased compared with the preoperative value [(6.2±0.8) points], the modified Merle d'Aubigné & Postel score [(13.2±2.1) points] and Harris hip score [(67.8±15.3) points] significantly increased compared with the preoperative values [(6.7±0.8) and (34.2±8.4) points], the vertical position of center of rotation [(22.5±5.2) mm] and the horizontal position of center of rotation [(40.7±2.6) mm] were significantly reduced compared with the preoperative values [(38.1±14.2) and (53.1±10.0) mm] ( P<0.05). At the last follow-up, the leg length discrepancy was (6.2±3.6) mm, showing no statistically significant difference from the preoperative value [(18.7±1.7) mm] ( P>0.05). At the last follow-up, no clear line at the cup-bone or augment-bone interface, or no possible prosthetic loosening or displacement was observed on the X-ray films. Conclusion:In delayed total hip arthroplasty after failed treatment of acetabular fractures, the customized 3D printed augment for repair of large bone defects in the acetabulum can reconstruct the normal rotation center of the hip joint, provide reliable stability for the cup prosthesis, and enable patients to obtain significant improvements in hip function.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 341-350, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992717

RESUMO

Objective:To compare the short-term efficacy between our self-designed intelligent robot-assisted minimally invasive reduction system and conventional freehand reduction assisted by fluoroscopy in the treatment of unstable pelvic fractures by robot or fluoroscopy-assisted internal fixation with percutaneous screws.Methods:A prospective randomized controlled trial was conducted to include eligible 35 patients with unstable pelvic fracture who were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from December 2021 to October 2022. They were randomized into 2 groups. The observation group[17 cases, 10 males and 7 females with an age of (44.0±17.4) years] was treated with robot-assisted minimally invasive reduction, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws; the control group[18 cases, 12 males and 6 females with an age of (38.8±15.0) years] was treated with freehand reduction assisted by fluoroscopy, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws. The 2 groups were compared in terms of operation time, intraoperative bleeding, successful reduction, reduction quality, incidence of surgical complications and postoperative functional scores.Results:The 2 groups were comparable because there were no significant differences in the preoperative general data between them ( P>0.05). The intraoperative fluoroscopy frequency[(32.4±17.5) times] and fluoroscopy time [(19.8±10.4) s] in the observation group were significantly lower or shorter than those in the control group [(60.8±26.6) times and (38.2±16.1) s], and the rate of successful reduction in the observation group was 100.0% (17/17), significantly higher than that in the control group[72.2% (13/18)] ( P<0.05). There was no significant difference between the 2 groups in intraoperative bleeding, operation time, reduction error, excellent and good rate of reduction after operation by Matta scoring, or Majeed functional score at 12 weeks after operation ( P>0.05). Conclusion:In the treatment of unstable pelvic fractures, since our self-designed intelligent robot-assisted minimally invasive reduction system can plan autonomously the reduction paths and accomplish minimally invasive reduction of the fracture with 3D images real-time monitoring, it is advantageous over conventional reduction methods in a higher success rate and less radiation exposure.

4.
Chinese Journal of Orthopaedic Trauma ; (12): 254-259, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992705

RESUMO

Objective:To explore the short-term efficacy of fixation with a 3D printed individualized custom-made plate in the treatment of elderly patients with periprosthetic femoral fracture.Methods:Retrospectively analyzed were the 5 elderly patients with periprosthetic femoral fracture who had been treated by fixation with a 3D printed individualized custom-made plate from January 2022 to July 2022 at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital. There were 3 males and 2 females, aged 81, 86, 77, 91 and 87 years, respectively. One left and 4 right limbs were affected. Vancouver classification: type B1 ( n=3), type B2 ( n=1), and type C ( n=1). The time from operation to injury was 5, 6, 10, 5 and 7 days, respectively. Preoperatively, the femur affected, prosthesis and individualized plate with a greater trochanteric hook, loop cable channel and bone-like trabecular microporous structure were custom-made by 3D printing according to 1:1 models. Virtual operations were simulated to formulate surgical protocols. The operation time, length of surgical incision, intraoperative blood loss and transfusion, hospital stay, hip function and complications at the last follow-up were recorded. Results:The 5 patients were followed up for 12, 7, 10, 3 and 6 months, respectively. There were no events of superficial incision or deep prosthesis infection. Respectively, the operation time was 1.8, 1.7, 2.3, 2.0 and 3.3 h; the length of surgical incision 31, 30, 38, 27 and 30 cm; the intraoperative bleeding volume 400, 300, 300, 500 and 600 mL; the length of hospital stay 8, 9, 15, 14 and 11 d. Four patients received intraoperative blood transfusion of 300, 900, 150 and 1, 050 mL, respectively. One patient died of a heart attack 3 months after discharge; another patient developed dyskinesia at the contralateral limb 3 months after discharge due to cerebral infarction and died of recurrent cerebral infarction 7 months after discharge. At the last follow-up, the Harris hip scores of 3 patients were 86, 77 and 69 points, respectively. None of the patients had complications like breakage or loosening of implants.Conclusion:In the treatment of elderly patients with periprosthetic femoral fracture, fixation with a 3D printed individualized custom-made plate may lead to fine limb function and good short-term curative efficacy.

5.
Chinese Journal of Orthopaedic Trauma ; (12): 372-379, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932341

RESUMO

Objective:To evaluate a self-designed intelligent robot-assisted minimally invasive reduction system in the reduction of unstable pelvic fractures by a cadaveric anatomic study.Methods:Ten unembalmed cadavers (7 male and 3 female ones) were used in this study. In each cadaveric specimen an unstable pelvic fracture was created in accordance with clinical case models (3 cases of type B1, 4 cases of type B2 and 3 cases of type C1 by the Tile classification). A self-designed intelligent robot-assisted minimally invasive reduction system was used to assist the reduction in the cadaveric models. Intraoperative registration and navigation time, autonomous reduction time, total operation time and reduction error were measured.Results:Effective reduction was completed in 10 bone models with the assistance of our self-designed intelligent robot-assisted minimally invasive reduction system. The time for intraoperative registration and navigation averaged 47.4 min (from 32 to 74 min), the autonomous reduction time 73.9 min (from 48 to 96 min), and the total operation time 121.3 min (from 83 to 170 min). The reduction error averaged 2.02 mm (from 1.67 to 2.62 mm), and the reduction results met the clinical requirements.Conclusion:Our self-designed intelligent robot-assisted minimally invasive reduction system is a new clinical solution for unstable pelvic fractures, showing advantages of agreement with clinical operative procedures, high reduction accuracy and operational feasibility, and reduced radiation exposure compared to a conventional operation.

6.
Chinese Journal of Orthopaedic Trauma ; (12): 194-199, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932312

RESUMO

Objective:To evaluate the emergency iliosacral screw fixation assisted by TiRobot for unstable posterior pelvic ring fracture.Methods:The 26 patients with unstable pelvic fracture were analyzed retrospectively who had undergone emergency iliosacral screw fixation at Department of Orthopedics & Traumatology, Beijing Jishuitan Hospital from June 2018 to December 2020. They were divided into 2 groups depending on whether orthopaedic TiRobot was used to assist screw insertion. In the observation group of 14 cases subjected to TiRobot-assisted insertion of iliosacral screws, there were 10 males and 4 females with an age of (45.9 ± 10.1) years; in the control group of 12 cases subjected to conventional manual insertion of iliosacral screws, there were 9 males and 3 females with an age of (49.2 ± 11.3) years. All the surgeries were conducted within 24 hours after injury. The 2 groups were compared in terms of screw insertion time, pin insertion, intraoperative blood loss, fluoroscopy time, postoperative screw position, fracture reduction and Harris hip score at the final follow-up.Results:The 2 groups were comparable because there was no significant difference between them in their preoperative general clinical data or follow-up time ( P>0.05). The screw insertion time [(16.1 ± 3.4) min] and fluoroscopy time [(8.1 ± 3.3) s] in the observation group were significantly shorter than those in the control group [(26.4 ± 5.4) min and (25.2 ± 7.4) s], and the pin insertions [1 (1, 2) times] and intraoperative blood loss [(10.5 ± 6.4) mL] in the former were significantly less than those in the latter [6 (3, 8) times and (24.8 ± 6.7) mL] (all P<0.05). Postoperatively, the sacroiliac screw position was excellent in 18 cases and good in 2 in the observation group while excellent in 14 cases, good in 2 and poor in 2 in the control group; the fracture reduction was excellent in 12 cases, good in one and fair in one in the observation group while excellent in 10 cases, good in one and fair in one in the control group, showing insignificant differences in the above comparisons ( P>0.05). There was no significant difference either in the Harris hip score at the final follow-up between the 2 groups ( P>0.05). Conclusion:Compared with conventional manual insertion of iliosacral screws, emergency iliosacral screw fixation assisted by TiRobot can effectively decrease surgical time and reduce operative invasion due to a higher accuracy rate of screw insertion.

7.
Chinese Journal of Orthopaedic Trauma ; (12): 533-537, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956552

RESUMO

Objective:To compare the short-term efficacy between femoral neck system (FNS) and cannulated compression screws (CCS) in the treatment of femoral neck fractures in young and middle-aged patients.Methods:A retrospective study was performed of the 29 young and middle-aged patients with femoral neck fracture who had been treated with FNS at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital from January 2020 to December 2020. A control group of another 29 patients with femoral neck fracture was selected who had been treated with CCS but matched in gender, age, and body mass index. In the CCS group, there were 14 males and 15 females with an age of (48.2±12.3) years; in the FNS group, there were 14 males and 15 females with an age of (48.2±12.0) years. The fracture reduction quality, operation time, intraoperative blood loss, and femoral neck shortening, hip joint function, Barthel index and health survey 12-item short form (SF-12) score at the last follow-up and complications during follow-up were compared between the 2 groups.Results:No significant difference was found in the preoperative general data or follow-up time between the 2 groups, showing comparability ( P>0.05). The intraoperative blood loss in the CCS group [20 (10, 50) mL] was significantly less than that in the FNS group [50 (20, 50) mL], and the femoral neck shortening at the last follow-up in the CCS group (grade 1 in 5 cases; grade 2 in 18 cases and grade 3 in 6 cases) was significantly worse than that in the FNS group (grade 1 in 21 cases, grade 2 in 6 cases and grade 3 in 2 cases) ( P<0.05). No significant difference was found regarding fracture reduction quality, operation time, complications during follow-up, or Merle D'Aubigne Postel score, Barthel index or SF-12 score at the last follow-up ( P>0.05). Conclusions:In the treatment of femoral neck fractures in young and middle-aged patients, both FNS and CCS are good options for internal fixation. However, FNS can reduce the severity of femoral neck shortening and maintain the length of femoral neck better than CCS.

8.
Chinese Journal of Orthopaedic Trauma ; (12): 513-518, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910004

RESUMO

Objective:To compare the perioperative data between the pararectus and ilioinguinal approaches in the internal fixation of acetabular fractures.Methods:A randomized controlled trial was conducted to enroll 74 patients with acetabular fracture who were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from June 2018 to January 2021. They were randomly divided into 2 groups. In group A of 37 cases, there were 28 males and 9 females with an age of (55.8±15.2) years, and 10 anterior column fractures, 7 anterior+posterior hemi-transverse fractures, one transverse fracture, 3 T-shaped fractures and 16 both column fractures according to Letournel-Judet classification. In group B of 37 cases, there were 28 males and 9 females with an age of (49.4±14.6) years, and 8 anterior column fractures, 6 anterior+ posterior hemi-transverse fractures, 2 transverse fractures, 2 T-shaped fractures and 19 both column fractures according to Letournel-Judet classification. Group A was subjected to open reduction and plate fixation via the pararectus approach while group B to open reduction and plate fixation via the ilioinguinal approach. The 2 groups were compared in terms of operation time, intraoperative blood loss, postoperative reduction and perioperative complications.Results:There were no significant differences in baseline data between the 2 groups, showing comparability between them ( P>0.05). The operation time in group A [150 (120, 180) min] was significantly shorter than that in group B [180 (150, 225) min] ( P<0.05). There were no significance differences between the 2 groups in intraoperative blood loss [800 (600, 1, 000) mL versus 1, 000(600, 1, 300) mL], rate of good to excellent reduction [91.9%(34/37) versus 78.4%(29/37)], or incidence of complications [24.3%(9/37) versus 45.9%(17/37)] ( P>0.05). Conclusion:Compared with the ilioinguinal approach, the pararectus approach can reduce operation time significantly in the internal fixation of acetabular fractures.

9.
Chinese Journal of Orthopaedic Trauma ; (12): 293-298, 2017.
Artigo em Chinês | WPRIM | ID: wpr-506006

RESUMO

Objective To evaluate the safety and efficiency of robot assisted surgery guided by damage control orthopaedics(DCO) in polytraumatised patients with pelvic ring injuries.Methods A retrospective review of the pelvic fracture database was performed.Twenty-six patients who had sustained a pelvic fracture from September 2012 to December 2015 were suitable for robot-assisted minimally invasive internal fixation.They were 17 men and 9 women,aged from 23 to 58 years (average,42.6 years).Their Injury Severity Score(ISS) ranged from 20 to 31 points (average,21.3 years).According to Tile classification,6 cases were type B2,3 type B3,9 type C2 and 8 type C3.Guided by DCO,the vital signs were stabilized by all means and the fractures treated by simple and temporary external fixation before the pelvic and other fractures were managed by the robot-assisted minimally invasive internal fixation.Demographics,times to operating room (TOR),time from acute stabilization to late definitive internal fixation (TAL),time for bone union,type of robot-assisted surgery for major fractures,length of stay (LOS),postoperative complications and mortality were recorded.The outcomes of the pelvis were evaluated at the final follow-up according to the Matta criteria.Results Of the 26 patients,robot-navigated percutaneous screwing was conducted with 23 sacroiliac screws in 19,with 9 ramus pubicus screws in 9,with 6 supraacetabular screws in 4,and with 4 both-column screws in 2 cases.TOR averaged 2.7 times,TAL 5.9 days,LOS at ICU 2.1 days,ICU admission rate 46.2% (12 of 26),hospital LOS 7.3 days,and time for pelvic bone union 79.0 days.None patients had postoperative complications related to the pelvic fracture and no one died.According to the Matta criteria at the final follow-ups,8 cases were excellent,11 good,5 fair and 2 poor,yielding an excellent and good rate of 73.1%.Conclusion Robot-navigated minimally invasive surgery plus DCO is effective,time saving and safe treatment for polytraumatised patients with pelvic ring injuries.

10.
Journal of Peking University(Health Sciences) ; (6): 274-280, 2017.
Artigo em Chinês | WPRIM | ID: wpr-512642

RESUMO

Objective:To evaluate the security and efficiency of a surgical robotic assisted percutaneous screw fixation for the treatment of pelvic and acetabular fractures.Methods: In the study,12 patients with pelvic and acetabular fractures who were treated in Beijing Jishuitan Hospital from January to April in 2016 were involved in this research.The research subjects were randomly divided into two groups: the experimental group and the control group.Robotic-assisted percutaneous sacroiliac screw internal fixations were performed under the guidance of fluoroscopy navigation in the experimental group;in the control group,doctors operated manually guided by fluoroscopy.Statistical analysis was performed on the total operation time,the intraoperative fluoroscopy time,the adjustment numbers of intraoperative guide wires,the excellent rate of screw placement and the incidence of adverse events in order to evaluate the security and efficiency of a surgical robotic assisted percutaneous screw fixation for the treatment of pelvic and acetabular fractures.Results: Eleven screws were placed in 7 patients from the experimental group,while 7 screws were placed in 5 patients from the control group in total.All the screw placement positions were satisfactory according to postoperative CT images.The excellent rates of screw placement position were 100% in both groups.However,the P value was 0.016 based on the comparison between the screws' distribution in the two groups which meant that the screw distribution of the experimental group was better than that of the control group.The average fluoroscopy time needed for screw insertion was (7.36±2.63) s in the experimental group while (41.80±13.99) s in the control group (P<0.001).This suggested that the difference between the two groups had statistical significances.Intra-operative fluoroscopy time of the experimental group was significantly smaller than that of the control group.The number of the average screw adjustment was (0.36±0.48) times in the experimental group while (9.00±3.06) times in the control group (P=0.003).This suggested that the difference of the number of the guide needle adjustment between the two groups had statistical significances,and the number of the experimental group was smaller than that of the control group.The average operation time was (43.86±49.06) min in the experimental group while only (29.00±12.14) min were needed in the control group (P=0.528).This suggested that the difference between the two groups had no statistical significance.That is,the total operation time of the two groups was equal.All the screws were in satisfactory positions according to validation results of CT scans.No complications such as screw breaking out the bone cortex and entering into the knee joint cavity,wound infection occurred.Conclusion: Surgical robots are suitable for robot-assisted percutaneous screw fixation in pelvic and acetabular fractures.Robot-assisted treatment of pelvic and acetabular fractures has significant advantages over manual operations including high accuracy,small perspective radiation,safety and efficiency.

11.
Chinese Journal of Orthopaedics ; (12): 528-534, 2017.
Artigo em Chinês | WPRIM | ID: wpr-608019

RESUMO

Objective To investigate the clinical results of Bi-plane robot navigation for cannulated screw fixation in the treatment of femoral neck fractures.Methods Between May 2011 and May 2015,86 patients with femoral neck fracture who were fixed with cannulated screws were retrospectively analyzed.The patients were divided into navigation group and non-navigation group according to whether the Bi-planar robot used for navigation or not.The patients were matched concerning gender,age and Garden classification.A total of 64 patients were included in the study.In navigation group,there were 32 cases,including 10 males and 22 females.The average age was 59.4±5.6 yr (range,51-68 yr).According to Garden classification,there were 1 case of type Ⅰ,7 cases of type Ⅱ,14 cases of type Ⅲ and 10 cases of type Ⅳ.In non-navigation group,there were 32 cases,including 12 males and 20 females.The average age was 59.1±4.9 yr (range,53-70 yr).According to Garden classification,there were 1 case of type Ⅰ,5 cases of type Ⅱ,18 cases of type Ⅲ and 8 cases of type Ⅳ.Sixty-four cases were all fixed with cannulated screws.The fluoroscopy time,fluoroscopy times,drilling times,times of cannulated screw replacement,cannulated screw insertion time,blood loss,relative position between any two cannulated screws in postoperative AP view and lateral view,the angle between each cannulated screw and the femoral neck axis,fracture healing time and functional score were recorded.Results The parameters in navigation group versus non-navigation group were as follows:the average fluoroscopy time was 10.1±2.9 s vs 36.8±7.5 s,the average fluoroscopy times was 11.4±3.2 vs 43.9±11.0,the average drilling times was 3.9±1.1 vs 18.5±3.2,the average times of cannulated screw replacement was 0.4±0.6 vs 1.0±0.7;the average blood loss was 29.4± 14.7 ml vs 50.2± 17.1 ml,cannulated screws placement time averaged 28.8±7.3 min vs 43.8±7.9 min.The angle between any of two cannulated screws averaged 3.1°±1.1° vs 7.3°± 1.2° in AP view and 2.9°±1.0° vs 4.4°±2.3° in lateral view,the angle between the cannulated screw and the femoral neck axis averaged 4.4°±1.6° vs 7.5°±1.7° in AP view and 4.9°±1.6° vs 8.0°±1.3° in lateral view.Significant differences were found concerning all above parameters between the two groups.Conclusion Bi-plane robot navigation technique helps more accurate cannulated screw fixation in the treatment of femoral neck fracture.This technique is less invasive.It decreases the time of screw insertion and reduces the radiation exposure.

12.
Journal of Xinxiang Medical College ; (12): 794-797, 2017.
Artigo em Chinês | WPRIM | ID: wpr-607511

RESUMO

Objective To analyze the effect of GC-rich DNA fragments on the level of transgenic expression in Chinese hamster ovary (CHO) celts and its position effect.Methods The synthetic DNA fragment with GC-rich was cloned into the 5'or 3'or both 5'and 3'ends of expression cassette of expression vector.Three new expression vectors (pIRES-G1,pIRES-G2 and pIRES-G3) which was inserted with the GC-rich DNA fragments in different position were transfected CHO ceils,respectively,and then was observed under fluorescence microscope;the control vector was pIRES-EGFP.Stable transfected cell lines were screened under G418,and enhanced green fluorescent protein(EGFP) expression was analyzed by flow cytometry and the transgenic copy number was detected by quantitative real-time quantitative polymerase chain reaction (qRT-PCR).Results Three expression vectors with a GC-rich DNA fragments in different position were constructed successfully.The insertion of GC-rich DNA fragments at 3'end and both 5',3'ends of the box of expression vector could obviously improve the expression level of vector in CHO cells;and the expression level of the stably transfected CHO cells increased 1.39 fold and 1.32 fold compared to the control vector,respectively;the transgene copy number increased 1.32 fold and 1.24 fold compared with the control vector.While the insertion of GC-rich DNA fragments at 5'end of expression cassette had no obvious effect on the level of gene expression.Conclusion The role of DNA fragment with GC-rich in improving the transgenic expression of CHO cells is related to its position in the vector.The insertion of GC-rich DNA fragments at 3'end and both 5',3'ends of the box of expression vector can improve transgenic expression.

13.
Chongqing Medicine ; (36): 2386-2388, 2017.
Artigo em Chinês | WPRIM | ID: wpr-620308

RESUMO

Objective To investigate the effect of different promoters on the expression level of transgene containing MAR expression vector in recombinant CHO cells.Methods The CMV promoter and 3-globin MAR were amplified by PCR,then CMV promoter was replaced the SV40 promoter in pCAT1 for constructing the expression vector droved by CMV promoter.The control vectors of pCAT1 and pCAT2 without containing MAR were simultaneously transfected into the CHO cells.Then the stably transfected cell line was screened by G418.The CAT gene expression level was analyzed by ELISA.Results The expression level of CAT enzyme in the cells transfected with MAR-containing vectors was increased compared with the cells transfected by pCATG and pCAT3 vectors without containing MAR,which were increased by 1.75 and 1.25 times respectively(P<0.05);but CAT enzyme expression level in the pCAT1 transfected cells droved by SV40 promotor with the MAR-containing expression vectors was 1.4 times higher than that in the pCAT2 vector droved by the CMV promoter(P<0.05).Conclusion MAR can enhance the transgene expression level in stably recombinant CHO cells,and the promoting efficiency of SV40 promoter and MAR combination is superior to that of CMV promoter and MAR combination.

14.
Chinese Journal of Orthopaedic Trauma ; (12): 662-668, 2017.
Artigo em Chinês | WPRIM | ID: wpr-615623

RESUMO

Objective To discuss the clinical outcomes of trochanteric digastric osteotomy and surgical hip dislocation for treatment of Pipkin Ⅳ fractures. Methods We retrospectively reviewed the 12 patients with Pipkin Ⅳ fracture who had been treated by trochanteric digastric osteotomy and surgical hip dislocation from February 2012 to June 2016. They were 10 males and 2 females, with an average age of 44. 1 years ( from 24 to 63 years ) . According to the Pipkin classification for femoral head fractures, 9 fractures were type Ⅰand 3 type Ⅱ; according to Letournel-Judet classification for acetabular fractures, 10 were posterior wall fractures ( 9 belonging to the posterior superior subgroup ) and 2 transverse plus posterior wall fractures ( one involving the posterior wall belonging to the posterior superior subgroup ) . The operation time, blood loss, complications and functional results were recorded. Results The operation time averaged 165 min ( from 150 to 195 min ); the blood loss averaged 850 mL ( from 500 to 1, 200 mL ) . A spring plate was used additionally for posterior wall fracture in 7 cases. All the 12 cases obtained an average follow-up of 19 months ( from 6 to 52 months ) . Motion function was fully recovered from 6 weeks to 4 months after operation in 2 cases of preoperative incomplete sciatic nerve injury and in one case of iatrogenic incomplete sciatic nerve injury. Anatomical reduction was achieved in all femoral head fractures. According to the Matta criteria for acetabular fractures, anatomical reduction was achieved in 9 cases, good reduction in 2 and poor reduction in one. Heterotopic ossification occurred in 4 cases ( gradeⅠin one, gradeⅡin 2 and gradeⅢin one by the Brooker grading system ) . The trochanteric osteotomy was repeated in one case. No femoral head avascular necrosis was found. According to the modified Merle d'Aubigné and Postel scoring at the final follow-ups, the functional results of the affected hip were excellent in 4 cases, good in 7 and poor in one. Conclusion Trochanteric digastric osteotomy and surgical hip dislocation is a safe and effective treatment for Pipkin Ⅳ fractures.

15.
Chinese Journal of Orthopaedic Trauma ; (12): 935-940, 2017.
Artigo em Chinês | WPRIM | ID: wpr-663105

RESUMO

Objective To explore the management of postoperative infection following open reduction and internal fixation for acetabular fractures.Methods Ten patients were treated and completely followed up in Beijing Jishuitan Hospital from February 2012 to December 2016 for postoperative infection after open reduction and internal fixation for acetabular fracture.They were 9 males and one female,aged from 14 to 64 years(mean,40.6 years).According to Letournel classification,there were 2 double-column fractures,2 anterior descending transverse fractures,2 anterior column fractures,one posterior wall fracture,and one posterior wall fracture.Eight cases developed surgical regional infection within 2 weeks after internal fixation,and 2 presented with symptoms of infection more than 3 months after fracture fixation.Vacuum sealing drainage (VSD) was used to treat one case of acute superficial infection;open debridement surgery,carrier with sensitive antibiotics and intravenous antibiotics were used to treat 7 cases of acute deep infection and 2 cases of chronic deep infection.Results The infection symptoms disappeared 9 days after removal of VSD device in the one case of acute superficial infection.Normal fracture union was achieved in 6 cases after their infection was controlled;4 cases had to undergo total hip arthroplasty because their articular structure was damaged after control of infection.The 10 patients were followed up for 6 to 54 months (mean,25.7 months).Their Harris scores at the last follow-up averaged 74.8 (from 32 to 92).Conclusions Negative-pressure wound therapy is an effective management for acute superficial infection after acetabular fracture.Deep acute infection needs early repeated debridement combined with sensitive antibiotic carrier to protect joint function.For infection which is difficult to control or chronic infection associated with structural damage,repeated debridement combined with sensitive antibiotic spacer is effective for infection control at the first stage and artificial total hip arthroplasty can be carried out at the second stage when the infection is controlled.

16.
Chinese Journal of Trauma ; (12): 427-430, 2015.
Artigo em Chinês | WPRIM | ID: wpr-473620

RESUMO

Objective To evaluate the incidence and imaging features of tibial plateau fracture combined with dislocation.Methods A total of 298 patients with intact imaging data treated for tibial plateau fracture from December 2012 to June 2014 were analyzed retrospcctively.Tilt angle of medial fragment fracture line,ratio of width of medial fragment to total plateau,surface area percentage,fragment height,and major displacement were measured on CT images using picture archiving and communication system (PACS).Results Eighteen patients (6.0%) had tibial plateau fractures combined with dislocation,with tilt angle of medial or posteromedial fragment fracture line of (62.1 ± 14.1)°.Eleven patients (61%) had split of the medial tibial plateau with surface area percentage of (46.3 ± 2.5) %,fragment height of (43.9 ± 6.2) mm,and major displacement of (5.3 ± 2.1) mm.Seven patients (39%) had posteromedial fragment fracture with surface area percentage of (25.1 ± 5.7) %,fragment height of (40.0 ± 10.1) mm,and major displacement of (4.8 ± 6.45) mm.Conclusions Fracture line of fracture-dislocation tibial plateau fracture is much often through the eminence or located at the lateral eminence with large medial or posteromedial fragments.Surgical approaches and directions of nailing should be considered properly according to the morphological characteristics.

17.
Chinese Journal of General Surgery ; (12): 374-376, 2009.
Artigo em Chinês | WPRIM | ID: wpr-393009

RESUMO

Objective To evaluate the necessity and safety of implanting temporary vena eava fihers to prevent pulmonary emboli in patients of lower extremity fractures concomitant with acute deep venous thrombosis(DVT). Methods A total of 782 patients with lower extremity fractures were complicated with DVT perioperatively. Among them, 91 received temporary vena cava filters implantation before orthopedic operations for the prevention of pulmonary embolism. All patients were followed up post-operation. Results Vena cava filters were successfully implanted in 89 patients. Mean implantation time was 27 days (range from 14 to 42 days). Thrombus trapped within the filters were found in 78 patients (87.6%) after the filters removal. Eight-two filters (92.1%) were retrived successfully at the first attempt as scheduled. Seven filters(7.9%) with big trapped thrombi were removed at the 2nd attempt after additional thrombolytic therapy. No patients needed a permanent filter. No fetal pulmonary embolism (PE) or other major complications were detected during the three to six months follow-ups period. Conclusion Temporary vena cava filter can reduce the incidence and mortality of pulmonary embolism as well as the occurrence of mid- or long-term complications in lower limb fracture patients complicated with DVT.

18.
Chinese Journal of Orthopaedic Trauma ; (12)2002.
Artigo em Chinês | WPRIM | ID: wpr-585670

RESUMO

Objective To investigate clinical feasibility, security, and effects of cannulated screw fixation of femoral neck fractures aided by the bi-planar navigation robot system. Methods Under the guidance of the robot system which was developed jointly by Beijing Aeronautics and Space University and our hospital, 15 pins were inserted into the femoral necks of 5 Synbone models. The difference between the distance of any 2 points at the entry point and that at the outlet point was measured in the 5 cases. The ratio (P) of the difference to the length of the pin within the femoral neck of the Synbone models was calculated to evaluate how parallel the 2 pins were. The fluoroscopic times and the radiation exposure time in the robot-aided treatment were recorded and compared with those in the 12 cases of conventional operations which were conducted in our department from June to September, 2005. Results P was about 0.003 7 to 0.018 1, and the X-ray exposure time in robot aided system was 2.32 s vs 28.30 s in the conventional operations. The average fluoroscopic times in robot aided system were 4.4 vs 54.3 in the conventional operations. Conclusion As the bi-planar navigation robot system can provide accurate space orientation and stable navigation route, and can decrease the X-ray radiation to the patient and staff, it has a significant value in clinical application.

19.
Chinese Journal of Orthopaedics ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-540952

RESUMO

Objective To evaluate and investigate the clinical feasibility and curative effects of the computer-assisted auto-frame navigation system for distal locking of tibial intramedullary nails. Methods The hardware components of the system consisted of a PC computer with a moniter, an auto mechanical stereotactical localization cubic frame, foot holder and localization apparatus; Self-designed navigation software was used for registration and real-time tool navigation control. 21 patients of tibial and fibluar fractures were treated with closed intramedullary nailing, all fractures were close, 6 in middle third, 12 in middle and lower third, 3 in lower third; C-arm alignment, registration time, fluoroscopic time and drilling time throughtout the locking procedure were recorded. Unreamed or reamed tibial nail sizes ranged from 8/300-11/330. Results All distal holes except 1 were locked successfully, in 9 of 41 holes(21.95%), the drilling ends were in contact with the locking canal, but without any damage to the nail and drilling ends and no adverse effects. The fluoroscopy time for a couple of screws was (2.23?0.31) seconds. Conclusion The computer-assisted auto-frame navigation system for distal locking is well designed, easy to operate and additional instruments are not necessary during the procedure; the developed system enables the physician to precisely navigate surgical instruments throughout the operation using just a few computer-calibrated radiographs. The total radiation exposure time for the procedure can be significantly reduced because additional X-ray exposure is not required. The cost is less expensive and apt to be extended.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA